MRC | Criteria | Characteristic |
---|
ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 225.0 DEG CELSIUS |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT |
AFZU | MAIN BODY INSIDE DIAMETER | 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZV | FIRST BRANCH INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
AFZW | SECOND BRANCH INSIDE DIAMETER | 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZX | THIRD BRANCH INSIDE DIAMETER | 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZX | THIRD BRANCH INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
AFZY | FOURTH BRANCH INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
AGAB | MAIN BODY WALL THICKNESS | 0.100 INCHES MAXIMUM AS SUPPLIED |
AGAC | FIRST BRANCH WALL THICKNESS | 0.100 INCHES MAXIMUM AS SUPPLIED |
AGAD | SECOND BRANCH WALL THICKNESS | 0.100 INCHES MAXIMUM AS SUPPLIED |
AGAG | DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES | 3.620 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 45.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAR | ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
CQBC | MINIMUM TENSILE STRENGTH | 1500 POUNDS PER SQUARE INCH |
FEAT | SPECIAL FEATURES | INSIDE ADHESIVE COATED |
STYL | STYLE DESIGNATOR | TRANSITION-1 TO 4 CABLES |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AFZU | MAIN BODY INSIDE DIAMETER | 1.620 INCHES MINIMUM AS SUPPLIED |
AGAC | FIRST BRANCH WALL THICKNESS | 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAE | THIRD BRANCH WALL THICKNESS | 0.100 INCHES MAXIMUM AS SUPPLIED |
AGAE | THIRD BRANCH WALL THICKNESS | 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAF | FOURTH BRANCH WALL THICKNESS | 0.100 INCHES MAXIMUM AS SUPPLIED |
AGAF | FOURTH BRANCH WALL THICKNESS | 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
HUES | COLOR | BLACK |
AFZW | SECOND BRANCH INSIDE DIAMETER | 1.060 INCHES MINIMUM AS SUPPLIED |
AGAD | SECOND BRANCH WALL THICKNESS | 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAQ | ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG | 10.0 NOMINAL AS SUPPLIED |
FLEX | FLEXIBILITY | SEMIRIGID |
AFZV | FIRST BRANCH INSIDE DIAMETER | 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AFZY | FOURTH BRANCH INSIDE DIAMETER | 0.490 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY |
AGAA | DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH | 3.580 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAB | MAIN BODY WALL THICKNESS | 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY |
AGAR | ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG | 15.0 NOMINAL AFTER UNRESTRICTED RECOVERY |
MATT | MATERIAL | PLASTIC,POLYOLEFIN,RT-301,RAYCHEM CORP |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 200.0 VOLTS PER MIL /0.001 INCH |