Thank you for considering Data Design Laboratories Corp part number 1000508-4, an item we carry that is listed with the NSN 5985-01-027-7364 and product description “Waveguideassembly.” This component is available for purchase through our website at this time, so complete the Request for Quote (RFQ) form provided below if you would like to receive pricing information for your comparisons. Simply offer our staff details like your desired quantity, budget, and delivery timeline to help us craft the best solution for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We aim to make the process of locating and procuring exact items simple, which is why we feature key listing details with every offering. For example, part number 1000508-4 was specifically produced by Data Design Laboratories Corp under CAGE Code 25154, and with the NSN 5985-01-027-7364, it belongs to FSC 5985 Antennas Waveguides and Related Equipment. Additionally, all stock comes delivered with any applicable qualifying certifications or manufacturer trace documentation for your further benefit. With all of this in mind, be sure to submit a request for part number 1000508-4 today, knowing we will be in touch shortly after reviewing your information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-027-7364 Item PartTypeName: WAVEGUIDE ASSEMBLY | 5985 | 010277364 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1000508-4 | 6 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 1.118 INCHES MINIMUM ALL FLANGES AND 1.126 INCHES MAXIMUM ALL FLANGES |
AHSY | FLANGE INSIDE HEIGHT | 0.493 INCHES MINIMUM ALL FLANGES AND 0.501 INCHES MAXIMUM ALL FLANGES |
AHSZ | FLANGE OUTSIDE WIDTH | 2.480 INCHES MINIMUM ALL FLANGES AND 2.520 INCHES MAXIMUM ALL FLANGES |
AHTA | FLANGE OUTSIDE HEIGHT | 1.730 INCHES MINIMUM ALL FLANGES AND 1.770 INCHES MAXIMUM ALL FLANGES |
AHTD | FLANGE DEPTH | 0.480 INCHES MINIMUM ALL FLANGES AND 0.520 INCHES MAXIMUM ALL FLANGES |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.401 INCHES MINIMUM ALL FLANGES ALL CONNECTION FACILITIES AND 0.411 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM |
CRFH | WAVEGUIDE INSIDE WIDTH | 1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM |
CRTL | CRITICALITY CODE JUSTIFICATION | CTFD |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | CONTACT TYPE ALL FLANGES |
CTFD | WAVEGUIDE LENGTH | 32.109 INCHES NOMINAL |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY 6061 ALL TUBING SEGMENT AND FLANGE |
STYL | STYLE DESIGNATOR | STRAIGHT TYPE |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.