Thank you for considering Dla Land And Maritime part number 87059-027, an item we carry that is listed with the NSN 5925-01-537-6131 and product description “Circuit Breaker.” This component is available for purchase through our website at this time, so complete the Request for Quote (RFQ) form provided below if you would like to receive pricing information for your comparisons. Simply offer our staff details like your desired quantity, budget, and delivery timeline to help us craft the best solution for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We aim to make the process of locating and procuring exact items simple, which is why we feature key listing details with every offering. For example, part number 87059-027 was specifically produced by Dla Land And Maritime under CAGE Code 037Z3, and with the NSN 5925-01-537-6131, it belongs to FSC 5925 Circuit Breakers. Additionally, all stock comes delivered with any applicable qualifying certifications or manufacturer trace documentation for your further benefit. With all of this in mind, be sure to submit a request for part number 87059-027 today, knowing we will be in touch shortly after reviewing your information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-537-6131 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015376131 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
87059-027 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
AKPX | Pole Quantity | 3 |
CPLM | Maximum Continuous Load Current Rating Per Pole | 6.0 AMPERES AC ALL LOCATIONS AND 6.0 AMPERES DC ALL LOCATIONS |
ABXD | Bushing Length | 0.380 INCHES MAXIMUM |
AJWX | Mounting Surface To Terminal End Distance | 1.780 INCHES MAXIMUM |
FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CQSM | Switch Location And Position Designation | INTERNAL AT POLE ONE |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
AEGJ | Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CSSX | Switch Current Rating And Type In Amps | 0.5 AC AND 0.5 DC |
ADAT | Body Width | 1.562 INCHES MAXIMUM |
CPRX | Actuator Position Designation | AT POLE TWO |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
ADTV | Case Material | METAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
CPRW | Actuator Function | TRIP-RESET |
CSWP | Switch Voltage Rating And Type In Volts | 120.0 AC AND 50.0 DC |
CRTK | Switch Terminal Type | TAB, SOLDER LUG |
THSD | Thread Series Designator | UNEF |
CQJX | Nominal Thread Size | 0.375 INCHES |
ADAQ | Body Length | 1.937 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.875 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 6 WIRE HOOK |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.625 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 500.0 DC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.055 MINIMUM AT 200 PCT ALL LOCATIONS AND 2.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CPRZ | Auxiliary Switch Function And Quantity | 1 ALARM |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.