Thank you for considering Dytecna Ltd part number P49 100 040, an item we carry that is listed with the NSN 5930-01-200-7881 and product description “Switch Thermostatic.” This component is available for purchase through our website at this time, so complete the Request for Quote (RFQ) form provided below if you would like to receive pricing information for your comparisons. Simply offer our staff details like your desired quantity, budget, and delivery timeline to help us craft the best solution for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We aim to make the process of locating and procuring exact items simple, which is why we feature key listing details with every offering. For example, part number P49 100 040 was specifically produced by Dytecna Ltd under CAGE Code K2449, and with the NSN 5930-01-200-7881, it belongs to FSC 5930 Switches. Additionally, all stock comes delivered with any applicable qualifying certifications or manufacturer trace documentation for your further benefit. With all of this in mind, be sure to submit a request for part number P49 100 040 today, knowing we will be in touch shortly after reviewing your information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-01-200-7881 Item PartTypeName: SWITCH,THERMOSTATIC | 5930 | 012007881 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
A46-3122 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT AND HUMIDITY RESISTANT AND VIBRATION RESISTANT |
ABHP | OVERALL LENGTH | 2.680 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 1.380 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.070 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.218 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.740 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.220 INCHES NOMINAL |
AEVT | CAPILLARY TUBE LENGTH | 24.00 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE |
AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BRACKET AND SLOT AND UNTHREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY CLOSED,MOMENTARY ACTION |
CSCF | TERMINAL TYPE | QUICK DISCONNECT,MALE |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 27.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 35.50 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
STYL | STYLE DESIGNATOR | RECTANGULAR |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.