Thank you for considering Eaton Corporation part number AM2-Z596-1, an item we carry that is listed with the NSN 5925-01-444-5076 and product description “Circuit Breaker.” This component is available for purchase through our website at this time, so complete the Request for Quote (RFQ) form provided below if you would like to receive pricing information for your comparisons. Simply offer our staff details like your desired quantity, budget, and delivery timeline to help us craft the best solution for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We aim to make the process of locating and procuring exact items simple, which is why we feature key listing details with every offering. For example, part number AM2-Z596-1 was specifically produced by Eaton Corporation under CAGE Code 74193, and with the NSN 5925-01-444-5076, it belongs to FSC 5925 Circuit Breakers. Additionally, all stock comes delivered with any applicable qualifying certifications or manufacturer trace documentation for your further benefit. With all of this in mind, be sure to submit a request for part number AM2-Z596-1 today, knowing we will be in touch shortly after reviewing your information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-444-5076 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014445076 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AM2-Z596-1 | 5 | 9 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MAXIMUM AT 200 PCT FIRST LOCATION |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
MRC | Decoded Requirement | Clear Text Reply |
CPLM | Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES DC SINGLE LOCATION |
AJEC | Boss Height | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
AKPX | Pole Quantity | 2 |
FREQ | Frequency In Hertz | 60.0 FIRST LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT FIRST LOCATION |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY FIRST LOCATION |
CPRL | Trip Release Characteristic | INSTANTANEOUS SECOND LOCATION |
CPRQ | Reset Method | MANUAL |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
ADAT | Body Width | 1.480 INCHES MINIMUM AND 1.520 INCHES MAXIMUM |
AXHR | Mounting Facility Type And Quantity | 4 CLIP |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPSM | Internal Trip Release Configuration | RELAY TRIP SECOND LOCATION |
CPSM | Internal Trip Release Configuration | SERIES TRIP FIRST LOCATION |
AJWX | Mounting Surface To Terminal End Distance | 2.850 INCHES MAXIMUM |
ADTV | Case Material | PLASTIC |
ADAQ | Body Length | 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC SINGLE LOCATION |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |