Thank you for considering Federal Pacific Electric Co part number NE231050, an item we carry that is listed with the NSN 5925-00-159-0444 and product description “Circuit Breaker.” This component is available for purchase through our website at this time, so complete the Request for Quote (RFQ) form provided below if you would like to receive pricing information for your comparisons. Simply offer our staff details like your desired quantity, budget, and delivery timeline to help us craft the best solution for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We aim to make the process of locating and procuring exact items simple, which is why we feature key listing details with every offering. For example, part number NE231050 was specifically produced by Federal Pacific Electric Co under CAGE Code 79443, and with the NSN 5925-00-159-0444, it belongs to FSC 5925 Circuit Breakers. Additionally, all stock comes delivered with any applicable qualifying certifications or manufacturer trace documentation for your further benefit. With all of this in mind, be sure to submit a request for part number NE231050 today, knowing we will be in touch shortly after reviewing your information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-159-0444 Item PartTypeName: CIRCUIT BREAKER | 5925 | 001590444 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
S1532392 | 1 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CWJK | CASE MATERIAL | PLASTIC |
FEAT | SPECIAL FEATURES | MTG HOLES IN 2 ROWS OF 3,1.375 BY 4.844 IN. C TO C |
TTQY | TERMINAL TYPE AND QUANTITY | 6 SCREW |
ABHP | OVERALL LENGTH | 6.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.969 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.125 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL |
AKPX | POLE QUANTITY | 3 |
APNQ | ARC QUENCHING METHOD | DEION |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC AND 15.0 AMPERES DC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC AND 125.0 DC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC AND 5000.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 210.000 MINIMUM AND 4200.000 MAXIMUM ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP W/SEPARATE RESET |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 210.000 MINIMUM AT 125 PCT AND 4200.000 MAXIMUM AT 125 PCT AND 20.000 MINIMUM AT 200 PCT AND 105.000 MAXIMUM AT 200 PCT AND 8.000 MINIMUM AT 300 PCT AND 23.000 MAXIMUM AT 300 PCT ALL LOCATIONS |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote