Thank you for considering General Dynamics Ots Global Inc part number 500471-1, an item we carry that is listed with the NSN 5950-01-318-6661 and product description “Transformerassembly.” This component is available for purchase through our website at this time, so complete the Request for Quote (RFQ) form provided below if you would like to receive pricing information for your comparisons. Simply offer our staff details like your desired quantity, budget, and delivery timeline to help us craft the best solution for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We aim to make the process of locating and procuring exact items simple, which is why we feature key listing details with every offering. For example, part number 500471-1 was specifically produced by General Dynamics Ots Global Inc under CAGE Code 21562, and with the NSN 5950-01-318-6661, it belongs to FSC 5950 Coils and Transformers. Additionally, all stock comes delivered with any applicable qualifying certifications or manufacturer trace documentation for your further benefit. With all of this in mind, be sure to submit a request for part number 500471-1 today, knowing we will be in touch shortly after reviewing your information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-318-6661 Item PartTypeName: TRANSFORMER ASSEMBLY | 5950 | 013186661 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
11-00151-001 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 2.390 INCHES MINIMUM AND 2.430 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.730 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.770 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.410 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.450 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 5.068 INCHES MINIMUM AND 5.088 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.117 INCHES MINIMUM AND 2.217 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.115 INCHES MINIMUM SINGLE GROUP AND 0.135 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL ALL COMPONENTS |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 195.5 VOLT-AMPERE ALL COMPONENTS |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL ALL COMPONENTS |
AEHZ | MAXIMUM OPERATING TEMP | 104.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS ALL SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS SINGLE PRIMARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 1ST COMPONENT AND 2 SECONDARY 1ST COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 2ND COMPONENT AND 4 SECONDARY 2ND COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.7 AMPERES AC NOMINAL ALL COMPONENTS SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 15.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 640.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 75.0 MILLIAMPERES AC MINIMUM 1ST COMPONENT 2ND SECONDARY AND 400.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 800.0 MILLIAMPERES AC NOMINAL 1ST COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.0886 1ST COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.540 2ND COMPONENT 4TH SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.700 ALL COMPONENTS SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.7932 2ND COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 4.300 2ND COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 52.200 2ND COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 7.800 1ST COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 19.44 VOLTS-AMPERES 1ST COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 195.5 VOLTS-AMPERES ALL COMPONENTS SINGLE PRIMARY |
CRMJ | WINDING POWER RATING | 2.4 VOLTS-AMPERES 2ND COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 2.56 VOLTS-AMPERES 2ND COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 2.62 VOLTS-AMPERES 2ND COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 44.96 VOLTS-AMPERES 1ST COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 45.824 VOLTS-AMPERES 2ND COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL ALL COMPONENTS SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 14.70 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY AND 56.90 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY AND 71.60 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 159.70 AC VOLTS NOMINAL 2ND COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 24.30 AC VOLTS NOMINAL 1ST COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 25.60 AC VOLTS NOMINAL 2ND COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.20 AC VOLTS NOMINAL 2ND COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 33.85 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 38.30 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 41.50 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 70.90 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 74.10 AC VOLTS NOMIN |
TEST | TEST DATA DOCUMENT | 16340-11-00151 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
TTQY | TERMINAL TYPE AND QUANTITY | 30 TURRET |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote