Thank you for considering General Electric Company part number 9T56Y2357, an item we carry that is listed with the NSN 5950-01-007-1792 and product description “Transformer Power.” This component is available for purchase through our website at this time, so complete the Request for Quote (RFQ) form provided below if you would like to receive pricing information for your comparisons. Simply offer our staff details like your desired quantity, budget, and delivery timeline to help us craft the best solution for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We aim to make the process of locating and procuring exact items simple, which is why we feature key listing details with every offering. For example, part number 9T56Y2357 was specifically produced by General Electric Company under CAGE Code 21150, and with the NSN 5950-01-007-1792, it belongs to FSC 5950 Coils and Transformers. Additionally, all stock comes delivered with any applicable qualifying certifications or manufacturer trace documentation for your further benefit. With all of this in mind, be sure to submit a request for part number 9T56Y2357 today, knowing we will be in touch shortly after reviewing your information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-007-1792 Item PartTypeName: TRANSFORMER,POWER | 5950 | 010071792 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
9T56Y2357 | 5 | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 12.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL SINGLE GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.938 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.250 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.375 INCHES MAXIMUM |
AGAV | END ITEM IDENTIFICATION | COLIVER PERRY CLASS FFG,VIRGINIA CLASS CGN (41),ARLEIGH BURKE CLASS DDG,SPRUANCE CLASS DD (963),NIMITZ CLASS CVN,KIDD CLASS DDG,TICONDEROGA CLASS CG (47),FORRESTAL CLASS CV,WASP CLASS LHD. |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |