Thank you for considering Lockheed Martin Librascope part number L504000374, an item we carry that is listed with the NSN 5950-00-421-2551 and product description “Transformer Power.” This component is available for purchase through our website at this time, so complete the Request for Quote (RFQ) form provided below if you would like to receive pricing information for your comparisons. Simply offer our staff details like your desired quantity, budget, and delivery timeline to help us craft the best solution for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We aim to make the process of locating and procuring exact items simple, which is why we feature key listing details with every offering. For example, part number L504000374 was specifically produced by Lockheed Martin Librascope under CAGE Code 36090, and with the NSN 5950-00-421-2551, it belongs to FSC 5950 Coils and Transformers. Additionally, all stock comes delivered with any applicable qualifying certifications or manufacturer trace documentation for your further benefit. With all of this in mind, be sure to submit a request for part number L504000374 today, knowing we will be in touch shortly after reviewing your information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-421-2551 Item PartTypeName: TRANSFORMER,POWER | 5950 | 004212551 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
L504000374 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 4.225 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 150.0 HERTZ MINIMUM SINGLE COMPONENT AND 500.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.780 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.410 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.850 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 14.14 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 70.70 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TEST | TEST DATA DOCUMENT | 10001-2550805 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 5 WIRE HOOK |