Thank you for considering Microwave Engineering Corporation part number TS645648, an item we carry that is listed with the NSN 5985-01-389-1927 and product description “Waveguideassembly.” This component is available for purchase through our website at this time, so complete the Request for Quote (RFQ) form provided below if you would like to receive pricing information for your comparisons. Simply offer our staff details like your desired quantity, budget, and delivery timeline to help us craft the best solution for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We aim to make the process of locating and procuring exact items simple, which is why we feature key listing details with every offering. For example, part number TS645648 was specifically produced by Microwave Engineering Corporation under CAGE Code 06351, and with the NSN 5985-01-389-1927, it belongs to FSC 5985 Antennas Waveguides and Related Equipment. Additionally, all stock comes delivered with any applicable qualifying certifications or manufacturer trace documentation for your further benefit. With all of this in mind, be sure to submit a request for part number TS645648 today, knowing we will be in touch shortly after reviewing your information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-389-1927 Item PartTypeName: WAVEGUIDE ASSEMBLY | 5985 | 013891927 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
LE413-0402-0201 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.496 INCHES MINIMUM AND 0.504 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES FIRST CONNECTION FACILITY |
AHSX | FLANGE INSIDE WIDTH | 0.896 INCHES MINIMUM FIRST FLANGE |
FLEX | FLEXIBILITY | FLEXIBLE SINGLE TUBING SEGMENT |
MATT | MATERIAL | COPPER ALLOY ALL TUBING SEGMENT AND FLANGE |
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR EXTERNAL,RECTANGULAR |
AHSF | FLANGE QUANTITY | 2 |
AHSY | FLANGE INSIDE HEIGHT | 0.396 INCHES MINIMUM FIRST FLANGE AND 0.404 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM FIRST FLANGE AND 1.640 INCHES MAXIMUM FIRST FLANGE |
CTCJ | FLANGE STYLE | COVER TYPE FIRST FLANGE |
STYL | STYLE DESIGNATOR | THREE BEND TYPE |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM FIRST FLANGE AND 0.443 INCHES MAXIMUM FIRST FLANGE |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.500 |
AHTX | INSERTION LOSS IN DECIBELS | 0.230 |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.996 INCHES MINIMUM AND 1.004 INCHES MAXIMUM |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.896 INCHES MINIMUM AND 0.904 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.396 INCHES MINIMUM AND 0.404 INCHES MAXIMUM |