Thank you for considering Permoflux Corp part number 0WT711, an item we carry that is listed with the NSN 5950-00-646-3519 and product description “Transformer Power.” This component is available for purchase through our website at this time, so complete the Request for Quote (RFQ) form provided below if you would like to receive pricing information for your comparisons. Simply offer our staff details like your desired quantity, budget, and delivery timeline to help us craft the best solution for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We aim to make the process of locating and procuring exact items simple, which is why we feature key listing details with every offering. For example, part number 0WT711 was specifically produced by Permoflux Corp under CAGE Code 93615, and with the NSN 5950-00-646-3519, it belongs to FSC 5950 Coils and Transformers. Additionally, all stock comes delivered with any applicable qualifying certifications or manufacturer trace documentation for your further benefit. With all of this in mind, be sure to submit a request for part number 0WT711 today, knowing we will be in touch shortly after reviewing your information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-646-3519 Item PartTypeName: TRANSFORMER,POWER | 5950 | 006463519 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
01-1866 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABTB | MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | EXTERNAL INCLOSURE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 6.813 INCHES NOMINAL |
ADAT | BODY WIDTH | 4.813 INCHES NOMINAL |
ADAU | BODY HEIGHT | 7.438 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | OPEN |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | BRACKET SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 3 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 35.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY AND 21.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY AND 12.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CRMJ | WINDING POWER RATING | 7.6 KILOVOLT-AMPERES SINGLE COMPONENT ALL SECONDARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY AND 210.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY AND 330.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
TTQY | TERMINAL TYPE AND QUANTITY | 21 THREADED STUD |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.