Thank you for considering Schneider Electric Gmbh part number FAL32070-1212, an item we carry that is listed with the NSN 5925-01-479-7763 and product description “Circuit Breaker.” This component is available for purchase through our website at this time, so complete the Request for Quote (RFQ) form provided below if you would like to receive pricing information for your comparisons. Simply offer our staff details like your desired quantity, budget, and delivery timeline to help us craft the best solution for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We aim to make the process of locating and procuring exact items simple, which is why we feature key listing details with every offering. For example, part number FAL32070-1212 was specifically produced by Schneider Electric Gmbh under CAGE Code 56303, and with the NSN 5925-01-479-7763, it belongs to FSC 5925 Circuit Breakers. Additionally, all stock comes delivered with any applicable qualifying certifications or manufacturer trace documentation for your further benefit. With all of this in mind, be sure to submit a request for part number FAL32070-1212 today, knowing we will be in touch shortly after reviewing your information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-479-7763 Item Description: Circuit Breaker | 5925 | 014797763 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Fal32070-1212 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 5.125 INCHES NOMINAL |
AKPX | Pole Quantity | 3 |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT |
CPLM | Maximum Continuous Load Current Rating Per Pole | 70.0 AMPERES AC ALL LOCATIONS |
MRC | Decoded Requirement | Clear Text Reply |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 10000.0 AC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.500 INCHES NOMINAL |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
AJEC | Boss Height | 0.125 INCHES NOMINAL |
CPRW | Actuator Function | TRIP-RESET |
AGAV | End Item Identification | 5820-01-454-0338 |
ADTV | Case Material | PLASTIC |
CPRX | Actuator Position Designation | AT POLE TWO |
ADAT | Body Width | 4.469 INCHES NOMINAL |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
ADAQ | Body Length | 6.000 INCHES NOMINAL |
TTQY | Terminal Type And Quantity | 6 COMPRESSION |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 5.125 INCHES NOMINAL |
ADAU | Body Height | 3.000 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.500 INCHES NOMINAL |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 40.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 125.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
AEBV | Unthreaded Mounting Hole Diameter | 0.190 INCHES NOMINAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |