Thank you for considering Sensata Technologies Inc part number UPGN-66-1-62-252, an item we carry that is listed with the NSN 5925-01-452-9853 and product description “Circuitbreaker.” This component is available for purchase through our website at this time, so complete the Request for Quote (RFQ) form provided below if you would like to receive pricing information for your comparisons. Simply offer our staff details like your desired quantity, budget, and delivery timeline to help us craft the best solution for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We aim to make the process of locating and procuring exact items simple, which is why we feature key listing details with every offering. For example, part number UPGN-66-1-62-252 was specifically produced by Sensata Technologies Inc under CAGE Code 81541, and with the NSN 5925-01-452-9853, it belongs to FSC 5925 Circuit Breakers. Additionally, all stock comes delivered with any applicable qualifying certifications or manufacturer trace documentation for your further benefit. With all of this in mind, be sure to submit a request for part number UPGN-66-1-62-252 today, knowing we will be in touch shortly after reviewing your information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-452-9853 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014529853 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
211726 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 125.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPLM | Maximum Continuous Load Current Rating Per Pole | 2.5 AMPERES DC ALL LOCATIONS |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 120.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERVOLTAGE ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 3500.0 AC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
AJEC | Boss Height | 0.625 INCHES NOMINAL |
ADAT | Body Width | 1.515 INCHES MAXIMUM |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
CPRX | Actuator Position Designation | AT POLE TWO |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADAQ | Body Length | 2.000 INCHES NOMINAL |
ADAU | Body Height | 2.232 INCHES MAXIMUM |
THSD | Thread Series Designator | UNC |
TTQY | Terminal Type And Quantity | 4 TAB W/SCREW |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
MRC | Decoded Requirement | Clear Text Reply |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote