Thank you for considering South Bay Cable Corp part number 80216, an item we carry that is listed with the NSN 6145-01-407-1696 and product description “Cable Specificationial Purpose Electrical.” This component is available for purchase through our website at this time, so complete the Request for Quote (RFQ) form provided below if you would like to receive pricing information for your comparisons. Simply offer our staff details like your desired quantity, budget, and delivery timeline to help us craft the best solution for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We aim to make the process of locating and procuring exact items simple, which is why we feature key listing details with every offering. For example, part number 80216 was specifically produced by South Bay Cable Corp under CAGE Code 51173, and with the NSN 6145-01-407-1696, it belongs to FSC 6145 Wire and Cable Electrical. Additionally, all stock comes delivered with any applicable qualifying certifications or manufacturer trace documentation for your further benefit. With all of this in mind, be sure to submit a request for part number 80216 today, knowing we will be in touch shortly after reviewing your information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6145-01-407-1696 Item PartTypeName: CABLE,SPECIAL PURPOSE,ELECTRICAL | 6145 | 014071696 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
80216 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 4TH POSITION TAPE ALL GROUPS |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR |
MATT | Material | PLASTIC POLYURETHANE 6TH POSITION JACKET CABLE |
MATT | Material | COPPER 2ND POSITION SHIELD BRAID, METALLIC SECOND CONDUCTOR |
SFTT | Surface Treatment | TIN 2ND POSITION SHIELD BRAID, METALLIC SECOND CONDUCTOR |
SFTT | Surface Treatment | TIN 3RD POSITION SHIELD BRAID, METALLIC THIRD GROUP |
CXCW | Conductor Form | STRANDED SINGLE CONDUCTOR |
MATT | Material | COPPER 5TH POSITION SHIELD BRAID, METALLIC THIRD GROUP |
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 3RD POSITION TAPE SECOND CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION SIXTH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 7TH CONDUCTOR |
AMQN | Conductor Quantity | 9 |
HUES | Color | BROWN 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 6TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 8TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 5TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 2ND CONDUCTOR |
HUES | Color | GREEN 1ST POSITION PRIMARY INSULATION SIXTH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 3RD CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 9TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 19 4TH CONDUCTOR |
BLNZ | Strand Quantity Per Conductor | 7 1ST CONDUCTOR |
HUES | Color | ORANGE 1ST POSITION PRIMARY INSULATION NINTH CONDUCTOR |
HUES | Color | BLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
AAGR | Cross-Sectional Shape Style | ROUND |
CXDC | Round Conductor Size | 16 AWG 4TH CONDUCTOR |
CXDC | Round Conductor Size | 16 AWG 5TH CONDUCTOR |
CXDC | Round Conductor Size | 18 AWG 9TH CONDUCTOR |
HUES | Color | GREEN 1ST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR |
CXDC | Round Conductor Size | 22 AWG 1ST CONDUCTOR |
CXDC | Round Conductor Size | 18 AWG 7TH CONDUCTOR |
MRC | Decoded Requirement | Clear Text Reply |
CXDG | Strand Awg Size Per Conductor | 26 9TH CONDUCTOR |
ABJH | Temp Rating | -28.0 DEG CELSIUS AND 65.0 DEG CELSIUS |
CXDG | Strand Awg Size Per Conductor | 29 5TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 26 7TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 3RD CONDUCTOR |
CXDC | Round Conductor Size | 16 AWG 3RD CONDUCTOR |
CXDC | Round Conductor Size | 16 AWG 6TH CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 30 1ST CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 6TH CONDUCTOR |
CXDC | Round Conductor Size | 18 AWG 8TH CONDUCTOR |
CXDT | Group Quantity | 4 |
MATT | Material | COPPER CORE CONDUCTOR ALL CONDUCTORS |
CXFG | Conductor Sequence Within Groups | FIRST CONDUCTOR FIRST GROUP AND SECOND CONDUCTOR FIRST GROUP |
CXFG | Conductor Sequence Within Groups | SEVENTH CONDUCTOR FOURTH GROUP AND EIGHTH CONDUCTOR FOURTH GROUP AND NINTH CONDUCTOR FOURTH GROUP |
CXDC | Round Conductor Size | 22 AWG 2ND CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 26 8TH CONDUCTOR |
MATT | Material | COPPER 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR |
HUES | Color | RED 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
CXDG | Strand Awg Size Per Conductor | 29 4TH CONDUCTOR |
SFTT | Surface Treatment | TIN 2ND POSITION SHIELD BRAID, METALLIC FIRST CONDUCTOR |
HUES | Color | WHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
SFTT | Surface Treatment | TIN CORE CONDUCTOR ALL CONDUCTORS |
CXDG | Strand Awg Size Per Conductor | 30 2ND CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE TEREPHTHALATE 3RD POSITION TAPE FIRST CONDUCTOR |
HUES | Color | YELLOW 1ST POSITION PRIMARY INSULATION FIFTH CONDUCTOR |
HUES | Color | YELLOW 1ST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR |
MATT | Material | PLASTIC POLYETHYLENE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
CXDQ | Conductor Arrangement And Quantity | 2 SINGLES AND 2 TWISTED PAIR AND 1 TRIPLES |
CXFG | Conductor Sequence Within Groups | FIFTH CONDUCTOR THIRD GROUP AND SIXTH CONDUCTOR THIRD GROUP |
CXFG | Conductor Sequence Within Groups | THIRD CONDUCTOR SECOND GROUP AND FOURTH CONDUCTOR SECOND GROUP |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION NINTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION FIFTH CONDUCTOR |
MATT | Material | PLASTIC POLYPROPYLENE 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
ADVL | Cross Section Outside Diameter | 0.665 INCHES NOMINAL |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote