Thank you for considering Square D Company part number KAL36125, an item we carry that is listed with the NSN 5925-00-208-4081 and product description “Circuit Breaker.” This component is available for purchase through our website at this time, so complete the Request for Quote (RFQ) form provided below if you would like to receive pricing information for your comparisons. Simply offer our staff details like your desired quantity, budget, and delivery timeline to help us craft the best solution for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We aim to make the process of locating and procuring exact items simple, which is why we feature key listing details with every offering. For example, part number KAL36125 was specifically produced by Square D Company under CAGE Code 56302, and with the NSN 5925-00-208-4081, it belongs to FSC 5925 Circuit Breakers. Additionally, all stock comes delivered with any applicable qualifying certifications or manufacturer trace documentation for your further benefit. With all of this in mind, be sure to submit a request for part number KAL36125 today, knowing we will be in touch shortly after reviewing your information.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-208-4081 Item Description: Circuit Breaker | 5925 | 002084081 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Kal36125 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 7.125 INCHES NOMINAL |
AKPX | Pole Quantity | 3 |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 600.0 AC ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 30000.0 AC ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 138.0 ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.500 INCHES NOMINAL |
CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS MAXIMUM ALL LOCATIONS |
AJEC | Boss Height | 0.125 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
CPRX | Actuator Position Designation | AT POLE TWO |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
ADTV | Case Material | PLASTIC |
ADAT | Body Width | 4.500 INCHES NOMINAL |
ADAQ | Body Length | 8.000 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 6.562 INCHES NOMINAL |
ADAU | Body Height | 3.500 INCHES NOMINAL |
CPLM | Maximum Continuous Load Current Rating Per Pole | 125.0 AMPERES AC ALL LOCATIONS |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 1.500 INCHES NOMINAL |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 150.000 MINIMUM AT 200 PCT AND |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 275.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
AEBV | Unthreaded Mounting Hole Diameter | 0.201 INCHES NOMINAL |
CPRW | Actuator Function | TRIP-RESET |
TTQY | Terminal Type And Quantity | 6 COMPRESSION |