Thank you for considering Thermotion Corp part number S1-2C, an item we carry that is listed with the NSN 6636-01-453-2322 and product description “Chamber Environment.” This component is available for purchase through our website at this time, so complete the Request for Quote (RFQ) form provided below if you would like to receive pricing information for your comparisons. Simply offer our staff details like your desired quantity, budget, and delivery timeline to help us craft the best solution for your needs.
Note : We Will Not Share Your Information To Any Third Parties.
We aim to make the process of locating and procuring exact items simple, which is why we feature key listing details with every offering. For example, part number S1-2C was specifically produced by Thermotion Corp under CAGE Code 20824, and with the NSN 6636-01-453-2322, it belongs to FSC 6636 Environmental Chambers And Related Equipment. Additionally, all stock comes delivered with any applicable qualifying certifications or manufacturer trace documentation for your further benefit. With all of this in mind, be sure to submit a request for part number S1-2C today, knowing we will be in touch shortly after reviewing your information.
MRC | Criteria | Characteristic |
---|---|---|
AMSE | Voltage Rating | 115.0 VOLTS NOMINAL |
AFMQ | Inside Height | 12.000 INCHES NOMINAL |
AFMW | Outside Height | 41.000 INCHES NOMINAL |
BDWT | Heating Method | ELECTRICAL |
BLST | Insulated Cabinet | PROVIDED |
ADJT | Inside Width | 16.000 INCHES NOMINAL |
HUES | Color | BLUE |
ADJV | Outside Width | 30.000 INCHES NOMINAL |
BQMN | Outer Door Quantity | 1 |
CWZY | Environmental Chamber Type | TEMPERATURE |
FAAZ | Phase | SINGLE |
ANPT | Power Rating | 40.0 VOLT-AMPERE NOMINAL |
AKYD | Accessory Components And Quantity | 2 1/2 HORSEPOWER COMPRESSORS |
BNDW | Cooling Coils For Below Room Temp Use | INCLUDED |
ACZB | Frequency Rating | 60.0 HERTZ NOMINAL |
BQML | Cabinet Mounting Type | STAND |
BQMP | Outer Door Material | STEEL |
BGXH | Water Jacket | PROVIDED |
BQMH | Cabinet Outer Wall Material | STEEL |
BQMJ | Cabinet Inner Wall Material | STEEL |
BQMR | Outer Door Insulation Feature | INCLUDED |
BHJQ | Door | PROVIDED |
BHGT | Circulation Method | MECHANICAL |
AFEF | Inside Depth | 11.000 INCHES NOMINAL |
BCXB | Outside Depth | 22.000 INCHES NOMINAL |
SFTT | Surface Treatment | LACQUER, FED SPEC 595-25185 |
MRC | Decoded Requirement | Clear Text Reply |
ASQJ | Operating Temp Range In Deg Celsius | -73.3 TO 177.0 |
FEAT | Special Features | PROGRAMMABLE TEMPERATURE CONTROLLER WITH DIGITAL DISPLAY (MODEL 2800);6PANE THERMAL WINDOW WITH SILICONE GASKETS; RS-232C OR IEEE-488 INTERFACE;DRY NITROGEN USED TO REDUCE MOISTURE CONTENT;MODIFIED TO INCLUDE REFRACTOR COLLIMATOR, MOTORIZED TARGET WHEEL AND VIBRATION ISOLATED BASE PLATE;USED TO TEST THE B-52 FLIR SENSOR ASSEMBLY (AN/AAQ-23) AND USED IN CONJUNCTION WITH IR RADIATION SOURCE CONTROL UNIT SR-80-2D |
AFPM | Assembly Form | ASSEMBLED |
ACDC | Current Type | AC |
MATT | Material | STEEL |
AZZH | Heat Source For Which Designed | INTEGRAL |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.